Zentralsterilisation - Ausgabe 1/2005

Zentralsterilisation - Ausgabe 1/2005

EDITORIAL

Das gesprochene Wort

AKTUELL

  • Aus dem Normenwerk: Zustimmung mit Kommentaren
  • Erster Workshop der bulgarischen Gesellschaft für Sterilgutversorgung "Bulsteri"
  • Dank an Herausgeberbeirat

HAUPTARBEITEN

A. Schneider:
Die neue Technische Regel Biologische Arbeitsstoffe im Gesundheitswesen und in der Wohlfahrtspflege (TRBA 250) Bedeutung für die Zentralsterilisation

A.C.P. de Bruijn, A.W. van Drongelen:
Beurteilung der Leistung von Krankenhaus-Dampfsterilisatoren mit dem europäischen Helixtest
(Zentr Steril 2005; 13 (1): -.)

Abstract
The Bowie & Dick test is used by manufacturers of steam sterilisers to design the sterilisation cycle in line with the requirements of the European standard for large steam sterilisers, EN285. Hospitals use it as the reference load in operational qualification and re-qualification and as the daily steam penetration test. However, textile packs are rarely sterilised in hospitals and complicated laparoscopic instruments provide a new challenge to the sterilisation cycle. It is time to review the value of the Bowie & Dick test in light of the items that are nowadays sterilised and perhaps choose another type of reference device for the design and qualification of large steam sterilisers (1). The Dutch National Institute for Public Health and the Environment conducted a study in 20 hospitals to determine whether the sterilisers are capable of passing the standard helix test according to EN867-5 (2). All sterilisers passed the Bowie & Dick test but of the 476 tests conducted with the helix 41% failed. The study shows that the ability of the steriliser to pass the helix test depends on the test conditions and the type of air removal. An air removal stage of the sterilisation cycle that is suitable to remove the air from a textile pack is not necessarily suitable for the air removal from hollow devices.
Schlüsselbegriffe

A. Draghici, J. Gauer, W. Michels, K. Roth*:
Untersuchungen zur Reinigungsleistung in Anlehnung an prEN/ISO 15883-1
(Zentr Steril 2005; 13 (1): -.)

Abstract
The radionuclide method was used to investigate comparatively the cleaning performance of automatic washing/disinfection processes on the critical joint areas of artery clips. The defined initial soil was radioactively marked coagulable blood. The results show the thorough effect of cleaning, which takes place in the presence of both an oxidative process stage, as well as a suitably composed detergent/hydrogen peroxide solution. Additionally, following elution of the joint areas, the direct measurements of the radionuclide method were correlated with the indirect determination of residual contamination in the eluate using the OPA method.

U. Kaiser:
Auswirkungen von nicht-kondensierbaren Gasen (NKG) in Dampfsterilisationsprozessen

R. Fleischhack:
Erarbeitung von Standardarbeitsanweisungen (SOP) für die Zentralsterilisationsabteilungen (ZSA) in Krankenhäusern in Mecklenburg-Vorpommern Praxisbericht

EMPFEHLUNGEN DES AK "QUALITÄT"

Leitfaden zur Erstellung von Standardarbeitsanweisungen


Herausgeber
Informationen auf dieser Seite mit freundlicher Genehmigung von: mhp-verlag GmbH
Adresse: Marktplatz 13
65183 Wiesbaden
Germany
Telefon: +49-(0)611-50593 0
Telefax: +49-(0)611-50593 11
Web: www.mhp-verlag.de
Email:

mhp steht für Medizin, Hygiene und Prävention. Der mhp-Verlag ist seit mehr als 20 Jahren Spezialist für Publikationen im Bereich der Hygiene.

Archiv
WFHSS - World Forum for Hospital Sterile Supply :: Publikationen :: Fachzeitschriften :: Zentralsterilisation :: Zentralsterilisation - Archiv :: Zentralsterilisation 1/2005

© 2010 WFHSS • Aktualisiert: 31. Mai 2009, 00:22 [GMT]